KNX SWITCH ACTUATOR 4F 16A 230VAC C-LOAD STANDARD 140ΜF CURRENT MEASUREMENT
0 ₽
KNX SWITCH ACTUATOR 4F 16A 230VAC C-LOAD STANDARD 140ΜF CURRENT MEASUREMENT
Информация о доставке
Нашли дешевле?
Введите адрес доставки
Описание
The MDT Switch Actuator receives KNX/EIB telegrams and switches up to 12 independent electrical loads . Each output uses a bistable relay and can be operated manually via a push button. A green LED indicates the switching status of each channel.
\n
\nThe outputs are parameterized individually via ETS. The device provides extensive functions like logical operation, status response, block functions, central function, delay functions and staircase lighting function. Additionally the device provides several time and scene control.
\n
\nThe MDT Switch Actuator offers current measurement for each channel and measurement of the total current. In dependence on the parameterization the measured data can be transmit in different data formats (mA/A/kW) onto the KNX bus. Additionally the device provides an hour/service interval meter. The integrated counter allows to capture the power consumption easily. The active power is calculated by the voltage and the factor cos phi.
\n
\nIf the mains voltage fails, all outputs hold their current position. After bus voltage failure or recovery the relay position is selected in dependence on the parameterization.
\n
\nThe MDT Switch Actuator is a modular installation device for fixed installation in dry rooms. It fits on DIN 35mm rails in power distribution boards or closed compact boxes. The MDT Switch Actuator has a separate power supply terminals for each channel.
\n
\n
FEATURES
\n- Production in Germany, certified according to ISO 9001 \n- NO and NC contact operation \n- Time functions (switch-on/switch-off delay, staircase light function) \n- Status response (active/passive) for each channel \n- Logical linking of binary data, 8 scenes per channel \n- Hour meter \n- Central switching functions and block functions \n- Adjustable behaviour in case of bus voltage failure or return \n- Each contact has an own supply phase \n- Integrated True RMS current measurement (current, kWh) \n- Current measurement range 10mA-20A \n- Fast reaction <1s at Master/Slave operation \n- Integrated counter to capture power consumption (Wh/kWh) \n- Quick application download (long frame support for ETS5) \n- Modular installation device for DIN 35mm rails \n- Integrated bus coupling unit \n- 3 years warranty \nTECHNICAL DETAILS & TYPES OVERVIEW
\nModel | \nAMS-0416.02 | \nAMS-0816.02 | \nAMS-1216.02 | \n
Number of outputs | \n4 | \n8 | \n12 | \n
Current measurement range | \n10mA - 20A | \n10mA - 20A | \n10mA - 20A | \n
Measuring inaccuracy | \n2% | \n2% | \n2% | \n
Sampling rate | \n2000 samples/500ms | \n2000 samples/500ms | \n2000 samples/500ms | \n
Output switching ratings: | \n|||
Ohmic load | \n16A | \n16A | \n16A | \n
Capacitive load | \n140uF | \n140uF | \n140uF | \n
Voltage | \n230VAC | \n230VAC | \n230VAC | \n
Maximum inrush current | \n600A/150μs \n250A/600μs | \n600A/150μs \n250A/600μs | \n600A/150μs \n250A/600μs | \n
Maximum load: | \n|||
Incandescent lamps | \n2500W | \n2500W | \n2500W | \n
Halogen lamps 230V | \n2500W | \n2500W | \n2500W | \n
Halogen lamps, electronic transformer* | \n1500W | \n1500W | \n1500W | \n
Fluorescent lamps, not compensated | \n2300W | \n2300W | \n2300W | \n
Fluorescent lamps, parallel comp. | \n1300W | \n1300W | \n1300W | \n
Max. number of electronic transformers | \n20 | \n20 | \n20 | \n
Output life expectancy (mechanical) | \n1.000.000 | \n1.000.000 | \n1.000.000 | \n
Specification KNX Interface | \nTP-256 with long frame support for ETS5 | \n||
Permitted wire gauge | \n|||
Screw terminal | \n1 x 0,5 - 4,0mm² solid core / finely stranded \n2 x 0,5 - 2,5mm² solid core / finely stranded (no mix allowed) | \n||
KNX busconnection terminal | \n0,8mm Ø, solid core | \n0,8mm Ø, solid core | \n0,8mm Ø, solid core | \n
Torque screw terminal | \n0,5Nm | \n0,5Nm | \n0,5Nm | \n
Power supply | \nKNX bus | \nKNX bus | \nKNX bus | \n
Power consumption KNX bus typ. | \n< 0,3W | \n< 0,4W | \n< 0,4W | \n
Operation temperature range | \n0 to + 45°C | \n0 to + 45°C | \n0 to + 45°C | \n
Enclosure | \nIP 20 | \nIP 20 | \nIP 20 | \n
Dimensions MDRC (Space Units) | \n4SU | \n8SU | \n12SU | \n